Duff-Norton
electromechanical actuators are the best packaged
solution for your linear actuation needs. With
capacities ranging from 100 lbs to 100 tons, no one
offers a greater selection of both AC and DC models.
This extensive line of models is designed to meet the
requirements of the most challenging applications.
Benefiting from the latest in advanced design
techniques, manufacturing methods, and over three
decades of electromechanical product experience,
Duff-Norton Electromechanical Actuators last longer and
run smoother with minimal maintenance and no headaches.
If you have a linear actuation application, Duff-Norton
has the packaged solution for you. |
|
c |
|
|
|
|
100
lb(45kg) Capacity Actuator |

|
- Input Voltages of: 12 VDC or 24 VDC
- Standard stroke lengths of: 2, 4,
6, 8, 10 and 12 inches
- Adjustable limit switches -
optional
- Lifting speeds up to 60 in/min
- Pulse Generator - optional
|
|
TracMaster™
Series |
Model |
Stroke
Length (inches) |
Input
Voltage |
Clutch |
Limit
Switch |
Position
Feedback |
Machine
or Ball Screw |
Duty
Cycle (In/Hr) |
Lifting
Speed (In/Min) |
|
TMD100 |
TMD01-1406 |
2,4,6,8,10,12
|
12 VDC
|
|
|
|
M
|
585
|
39
|
| |
TMD01-1906
|
2,4,6,8,10,12
|
12 VDC
|
|
* |
|
M
|
450
|
30
|
| |
TMD01-2406
|
2,4,6,8,10,12
|
24 VDC
|
|
|
|
M
|
900
|
60
|
| |
TMD01-2906 |
2,4,6,8,10,12 |
24
VDC |
|
* |
|
M |
870 |
58
|
|
|
|
250
lb(113kg) Capacity Actuator (Parallel Mount Motor) |

|
- Input Voltages of: 12 VDC or 24 VDC
- Standard stroke lengths of: 2, 4,
6, 8, 10 and 12 inches
- Lifting speeds up to 41 in/min
- Adjustable limit switches -
optional
- Pulse generator - optional
|
|
TracMaster™
Series |
Model
|
Stroke
Length (inches) |
Input
Voltage |
Clutch |
Limit
Switch |
Position
Feedback |
Machine
or Ball Screw |
Duty
Cycle (In/Hr)
|
Lifting
Speed (In/Min) |
|
TMD250
|
TMD02-1406 |
2,4,6,8,10,12 |
12
VDC |
|
|
|
M |
375 |
25 |
| |
TMD02-1906 |
2,4,6,8,10,12 |
12
VDC |
|
*
|
|
M |
330
|
22
|
| |
TMD02-2406 |
2,4,6,8,10,12 |
24
VDC |
|
|
|
M |
630
|
42
|
| |
TMD02-2906 |
2,4,6,8,10,12 |
24
VDC |
|
* |
|
M
|
495
|
33
|
|
|
|
250
lb(113kg) Capacity Actuator (Right Angle Mount Motor) |

|
- Input Voltages of: 115 VAC, 60 Hz,
220 VAC, 50 Hz, 12 VDC and 24 VDC
- Standard stroke lengths of: 3,6,12,
and 18 inches
- Lifting speeds up to 86 in/min for
AC models and 143 in/min for DC models
- Offered with fully adjustable
internal limit switches or travel/load limiting
friction disc clutches.
- Potentiometer - optional
|
|
TracMaster™
Series |
Model |
Stroke
Length (inches) |
Input
Voltage |
Clutch |
Limit
Switch |
Position
Feedback |
Machine
or Ball Screw |
Duty
Cycle (In/Hr) |
Lifting
Speed (In/Min) |
|
TMA250-MP |
SPB3405
|
3,6,12,18
|
115
VAC (60 Hz) |
* |
|
|
M |
575 |
40 |
| |
SPB4405 |
3,6,12,18 |
220
VAC (50 Hz) |
* |
|
|
M |
435 |
34 |
| |
HSPB3405 |
3,6,12,18 |
115
VAC (60 Hz) |
* |
|
|
M |
500 |
86 |
|
TMD250-MP |
MPD3405 |
3,6,12,18 |
12
VDC |
* |
|
|
M |
1250 |
60 |
| |
MPD3404 |
3,6,12,18 |
24
VDC
|
*
|
|
|
M
|
1200
|
66
|
| |
HMPD3405 |
3,6,12,18
|
12
VDC
|
*
|
|
|
M
|
1000
|
143
|
|
TMAL250-MP |
MPB3905
|
3,6,12,18
|
115
VAC (60 Hz) |
|
*
|
|
M
|
575
|
40
|
| |
MPB4905
|
3,6,12,18
|
220
VAC (50 Hz) |
|
*
|
|
M
|
435
|
34
|
| |
HMPB3905 |
3,6,12,18
|
115
VAC (60 Hz) |
|
*
|
|
M
|
500
|
86
|
| |
PMPB3905 |
3,6,12,18
|
115
VAC (60 Hz) |
|
*
|
*
|
M
|
575
|
40
|
| |
PMPB4905 |
3,6,12,18
|
220
VAC (50 Hz) |
|
*
|
*
|
M
|
435
|
34
|
| |
PHMPB3905 |
3,6,12,18
|
115
VAC (60 Hz) |
|
*
|
*
|
M
|
500
|
86
|
|
TMDL250-MP |
MPD3905 |
3,6,12,18
|
12
VDC
|
|
*
|
|
M
|
1250
|
60
|
| |
MPD3904 |
3,6,12,18
|
24
VDC
|
|
*
|
|
M
|
1200
|
143
|
| |
HMPD3905 |
3,6,12,18
|
12
VDC
|
|
*
|
|
M
|
1000
|
66 |
|
|
|
500
lb(227kg) Capacity Actuator |

|
- Input Voltages of: 115 VAC,
60 Hz, 220 VAC, 50 Hz, 12 VDC and 24 VDC
- Standard stroke lengths of: 3,6,12,
and 18 inches
- Lifting speeds up to 79"/min
for AC models and 50"/min for DC models
- Offered with fully adjustable
internal limit switches or travel/load limiting
friction disc clutches.
- Potentiometer - optional
|
|
TracMaster™
Series |
Model |
Stroke
Length (inches) |
Input
Voltage |
Clutch |
Limit
Switch |
Position
Feedback |
Machine
or Ball Screw |
Duty
Cycle (In/Hr) |
Lifting
Speed (In/Min) |
|
TMA500-MP |
SPB6405 |
3,6,12,18
|
115VAC
(60 Hz) |
*
|
|
|
M
|
500
|
35
|
| |
SPB7405
|
3,6,12,18
|
220
VAC (50 Hz) |
*
|
|
|
M
|
435
|
32
|
| |
HSPB6405 |
3,6,12,18
|
115
VAC (60 Hz) |
*
|
|
|
M
|
500
|
79
|
|
TMD500-MP |
MPD6405 |
3,6,12,18 |
12
VDC
|
*
|
|
|
M
|
450
|
44
|
| |
MPD6404 |
3,6,12,18
|
24
VDC
|
*
|
|
|
M
|
500 |
50
|
|
TMAL500-MP |
MPB6905
|
3,6,12,18
|
115
VAC (60 Hz) |
|
*
|
|
M
|
500
|
35
|
| |
MPB7905
|
3,6,12,18
|
220
VAC (50 Hz) |
|
*
|
|
M
|
435
|
32
|
| |
HMPB6905 |
3,6,12,18
|
115
VAC (60 Hz) |
|
*
|
|
M
|
500
|
79
|
| |
PMPB6905 |
3,6,12,18
|
115
VAC (60 Hz) |
|
*
|
*
|
M
|
500
|
35
|
| |
PMPB7905 |
3,6,12,18
|
220
VAC (50 Hz) |
|
*
|
*
|
M
|
435
|
32
|
| |
PHMPB6905 |
3,6,12,18
|
115
VAC (60 Hz) |
|
*
|
*
|
M
|
500
|
79
|
|
TMDL500-MP |
MPD6905 |
3,6,12,18
|
12
VDC
|
|
*
|
|
M
|
450
|
44
|
| |
MPD6904 |
3,6,12,18
|
24
VDC
|
|
*
|
|
M
|
500
|
50
|
|
|
|
750
lb Capacity Actuator |

|
- Input Voltages of: 115 VAC, 60 Hz,
220 VAC, 50 Hz, 12 VDC and 24 VDC
- Standard stroke lengths of: 4,8,12
and 18 inches
- Lifting speeds up to 32" /min
for AC models and 24" /min for DC models
- Fully adjustable internal limit
switches are standard
- Potentiometer - optional
|
|
TracMaster™
Series |
Model |
Stroke
Length (inches) |
Input
Voltage |
Clutch |
Limit
Switch |
Position
Feedback |
Machine
or Ball Screw |
Duty
Cycle† (In/Hr) |
Lifting
Speed (In/Min) |
|
TMAL-750 |
LSPA3275
|
4,8,12,18
|
115
VAC (60 Hz) |
|
*
|
|
M
|
290
|
15
|
| |
LSPA4275
|
4,8,12,18
|
220
VAC (50 Hz) |
|
*
|
|
M
|
145
|
12
|
| |
HLSPA3275 |
4,8,12,18
|
115
VAC (60 Hz) |
|
*
|
|
M
|
480
|
32
|
| |
HLSPA4275 |
4,8,12,18
|
220
VAC (50 Hz) |
|
*
|
|
M
|
450
|
30
|
| |
PLSPA3275 |
4,8,12,18
|
115
VAC (60 Hz) |
|
*
|
*
|
M
|
290
|
15
|
| |
PLSPA4275 |
4,8,12,18
|
220
VAC (50 Hz) |
|
*
|
*
|
M
|
145
|
12
|
| |
PHLSPA3275 |
4,8,12,18
|
115
VAC (60 Hz) |
|
*
|
*
|
M
|
480
|
32
|
| |
PHLSPA4275 |
4,8,12,18
|
220
VAC (50 Hz)
|
|
*
|
*
|
M
|
450
|
30
|
|
TMDL750 |
LSPD2775 |
4,8,12,18
|
12
VDC
|
|
*
|
|
M
|
360
|
22
|
| |
LSPD2774 |
4,8,12,18
|
24
VDC
|
|
*
|
|
M
|
459
|
24
|
| |
PLSPD2775 |
4,8,12,18
|
12
VDC
|
|
*
|
*
|
M
|
360
|
22
|
| |
PLSPD2774 |
4,8,12,18
|
24
VDC
|
|
*
|
*
|
M
|
459
|
24
|
|
|
|
1000
lb(454kg) Capacity Actuators |

|
- Input Voltages of: 115 VAC, 60 Hz,
220 VAC, 50 Hz, 12 VDC and 24 VDC
- Standard stroke lengths of: 3,6,12,
18 and 24 inches
- Lifting speeds up to 53" /min
for AC models and 39" /min for DC models
- Fully adjustable internal limit
switches are standard
- Potentiometer - optional
|
|
TracMaster™ Series |
Model |
Stroke
Length
(inches) |
Input
Voltage |
Clutch |
Limit
Switch |
Position
Feedback |
Machine
or Ball Screw |
Duty
Cycle† (In/Hr) |
Lifting
Speed (In/Min) |
|
TMAL1000-HD |
SPA
3410
|
3,6,12,18,24 |
115
VAC (60 Hz) |
|
* |
|
B |
900
|
53 |
| |
SPA
4410
|
3,6,12,18,24
|
220
VAC (50 Hz)
|
|
*
|
|
B |
1000
|
50
|
| |
PSPA
3410
|
3,6,12,18,24
|
115
VAC (60 Hz)
|
|
*
|
*
|
B
|
900
|
53
|
| |
PSPA
4410 |
3,6,12,18,24
|
220
VAC (50 Hz)
|
|
*
|
*
|
B |
1000
|
50
|
|
TMDL1000-HD
|
LSPD2910
|
3,6,12,18,24
|
12
VDC
|
|
*
|
|
B
|
885
|
39
|
| |
LSPD2909
|
3,6,12,18,24
|
24
VDC
|
|
*
|
|
B
|
1085
|
38
|
| |
| | | | |